Bilirubin Jaundice Meter MBJ20
M & B MBJ20 Transcutaneous Bilirubin Jaundice Meter is a non-invasive diagnostic device designed to measure bilirubin levels in newborns quickly, safely, and accurately, without the need for blood sampling. Utilizing advanced optical technology, the MBJ20 enables healthcare professionals to perform real-time screening for neonatal jaundice, minimizing discomfort for infants while reducing the risk of infection associated with invasive procedures.
The device operates by analyzing the reflection of a specialized light spectrum from the subcutaneous tissue, providing precise total bilirubin readings within seconds. Its fast and accurate measurements make it ideal for use in neonatal care units, maternity wards, pediatric clinics, and community healthcare settings.
Designed with ergonomics and ease of use in mind, the MBJ20 features a lightweight, handheld form factor that can be operated comfortably with one hand. Its intuitive digital interface and clear display allow for quick reading of results, even in low-light conditions, supporting efficient workflow for medical staff.
Clinically validated for high accuracy and consistency, the MBJ20 reduces the need for repeated serum bilirubin tests, lowering operational costs while enhancing patient comfort. The system aligns with modern neonatal care standards that prioritize safety, efficiency, and the well-being of the infant.
With its combination of speed, precision, and non-invasive operation, the M & B MBJ20 is the ideal solution for healthcare providers seeking a reliable, patient-friendly method for monitoring bilirubin levels and supporting early intervention in neonatal jaundice.
Key Features
-
Non-Invasive Bilirubin Measurement
Provides accurate bilirubin readings without the need for blood sampling, reducing discomfort and stress for newborns. -
Fast and Real-Time Results
Delivers bilirubin levels within seconds, supporting prompt clinical decision-making. -
Advanced Optical Technology
Uses specialized light spectrum analysis for precise and reliable measurement of total bilirubin. -
Ergonomic Handheld Design
Lightweight and easy to operate with one hand, improving clinician comfort and workflow. -
Intuitive Digital Interface
Clear display and simple controls allow quick and easy reading of results. -
Clinically Validated Accuracy
Ensures consistent and reproducible readings, suitable for routine neonatal screening. -
Early Detection of Neonatal Jaundice
Enables timely intervention to prevent complications associated with high bilirubin levels. -
Reduces Need for Blood Tests
Minimizes repeated serum bilirubin sampling, lowering operational costs and patient discomfort. -
Portable and User-Friendly
Compact design allows easy use in neonatal units, clinics, or community healthcare settings. -
Supports Modern Neonatal Care
Aligns with best practices for safe, efficient, and infant-centered care.
Key Benefits
-
Enhanced Patient Comfort
Non-invasive measurement eliminates the need for blood sampling, reducing pain and stress for newborns. -
Rapid and Reliable Results
Provides bilirubin readings in seconds, supporting timely clinical decision-making. -
Early Detection of Neonatal Jaundice
Enables prompt identification of high bilirubin levels, helping prevent complications. -
Reduced Risk of Infection
Non-invasive operation minimizes exposure to potential blood-borne pathogens. -
Cost-Effective Screening Solution
Reduces reliance on repeated serum bilirubin tests, lowering laboratory and operational costs. -
Consistent and Accurate Performance
Clinically validated technology ensures reliable and repeatable results for routine neonatal monitoring. -
Easy to Use
Intuitive controls and clear display allow quick operation by clinicians and nurses. -
Portable and Versatile
Lightweight, handheld design is suitable for neonatal units, maternity wards, pediatric clinics, or community healthcare settings. -
Supports Modern Neonatal Care Standards
Aligns with best practices focused on safety, efficiency, and infant-centered care. -
Improves Parent and Caregiver Confidence
Gentle, needle-free testing reassures parents and enhances the overall care experience.
Technical Specifications
-
Measurement Method:
Transcutaneous optical bilirubin measurement -
Measured Parameter:
Total bilirubin (TcB) -
Measurement Range:
Suitable for neonatal bilirubin screening (refer to manufacturer for exact range) -
Measurement Time:
Results within seconds -
Accuracy:
Clinically validated for precise and reproducible measurements -
Display:
Digital LCD screen for easy reading -
User Interface:
Intuitive controls for simple operation -
Power Supply:
Rechargeable battery or AC power (model dependent) -
Ergonomics:
Handheld, lightweight design for one-handed operation -
Patient Type:
Neonates and newborns -
Clinical Applications:
Neonatal jaundice screening and bilirubin monitoring -
Safety Features:
Non-invasive operation minimizes patient risk -
Operating Environment:
Neonatal units, NICU, maternity wards, pediatric clinics, and community healthcare settings -
Calibration:
Factory calibrated with long-term stability -
Compliance:
Meets applicable medical device safety and quality standards

Reviews
There are no reviews yet.