Philips Volcano Core M2 Vascular System
The Philips Volcano Core M2 Vascular System is a state-of-the-art intravascular diagnostic platform designed to provide accurate, high-resolution imaging and measurements for cardiovascular assessment. Engineered for use in catheterization laboratories, the Core M2 delivers precise intravascular imaging and functional assessment to guide interventional procedures, helping clinicians make informed decisions and improve patient outcomes.
Equipped with advanced intravascular ultrasound (IVUS) and physiology tools, the Core M2 enables detailed evaluation of coronary and peripheral arteries, including plaque characterization, vessel sizing, and assessment of lesion severity. This facilitates optimal stent selection, placement, and post-procedural evaluation, minimizing complications and enhancing procedural success.
The Core M2 features an intuitive, touchscreen interface that simplifies operation, supports efficient workflow, and provides real-time display of intravascular images and physiologic measurements. Its compact, ergonomic design allows seamless integration into busy catheterization labs without compromising performance or accessibility.
With compatibility for a wide range of Philips Volcano catheters and pressure/flow guidewires, the system supports comprehensive vascular assessment in coronary, peripheral, and structural heart interventions. Built with reliability and precision in mind, the Philips Volcano Core M2 Vascular System ensures consistent, reproducible results for interventional cardiologists seeking high-quality intravascular diagnostics.
Key Features
-
Advanced Intravascular Imaging – Supports high-resolution IVUS for detailed visualization of vessel structure and plaque morphology.
-
Physiology Assessment Tools – Measures fractional flow reserve (FFR), instantaneous wave-free ratio (iFR), and other hemodynamic parameters.
-
Real-Time Data Display – Touchscreen interface provides live imaging and physiologic measurements for immediate clinical decision-making.
-
Comprehensive Vessel Analysis – Enables accurate vessel sizing, lesion assessment, and stent planning for coronary and peripheral interventions.
-
Wide Catheter Compatibility – Works with Philips Volcano IVUS catheters, pressure guidewires, and flow measurement devices.
-
Enhanced Workflow Efficiency – Intuitive interface and streamlined software reduce procedure time and complexity.
-
Compact and Ergonomic Design – Easily integrates into catheterization labs without occupying excessive space.
-
Reliable Performance – Delivers consistent, reproducible measurements to support confident interventional decisions.
-
Support for Multiple Vascular Territories – Applicable in coronary, peripheral, and structural heart procedures.
-
High-Quality Imaging & Analysis Software – Provides plaque characterization, vessel remodeling assessment, and post-intervention evaluation.
Key Benefits – Philips Volcano Core M2 Vascular System
-
Enhances diagnostic accuracy with high-resolution IVUS imaging and precise physiologic measurements.
-
Supports optimal interventional planning by providing detailed vessel sizing, lesion characterization, and stent guidance.
-
Improves patient outcomes through informed decision-making and reduced procedural complications.
-
Streamlines workflow with an intuitive touchscreen interface and real-time data display.
-
Reduces procedure time by combining imaging and physiology assessment in a single platform.
-
Versatile application across coronary, peripheral, and structural heart interventions.
-
Ensures reliable and reproducible results to build clinician confidence in interventional decisions.
-
Facilitates comprehensive post-procedure evaluation for stent placement and vessel remodeling.
-
Integrates seamlessly into cath lab environments with compact, ergonomic design.
-
Provides compatibility with a wide range of Philips Volcano catheters and guidewires for flexible clinical use.
Technical Specifications
System Overview
-
Model: Core M2 Vascular System
-
Manufacturer: Philips Volcano
-
Type: Intravascular diagnostic system for imaging and physiologic assessment
-
Applications: Coronary, peripheral, and structural heart interventions
Imaging & Measurement
-
Intravascular Ultrasound (IVUS): High-resolution grayscale imaging for vessel wall and plaque characterization
-
Physiology Measurements: Supports Fractional Flow Reserve (FFR), Instantaneous Wave-Free Ratio (iFR), and pressure/flow assessments
-
Real-Time Display: Touchscreen monitor showing live IVUS images and physiologic data
-
Plaque Analysis: Automated and manual tools for quantifying plaque burden and vessel dimensions
-
Post-Intervention Assessment: Evaluate stent expansion and apposition
Catheter & Guidewire Compatibility
-
Compatible with Philips Volcano IVUS catheters
-
Supports pressure guidewires and flow measurement devices
-
Adaptable to a variety of coronary and peripheral vessels
Display & User Interface
-
Monitor: High-resolution touchscreen
-
Controls: Intuitive software with easy navigation for image acquisition and analysis
-
Data Output: Digital storage, DICOM export, and reporting capabilities
Physical & Environmental
-
Dimensions: Approximately 15 × 18 × 12 inches (38 × 46 × 30 cm) – varies by configuration
-
Weight: ~25 lbs (11.3 kg)
-
Power Requirements: 100–240 V AC, 50/60 Hz
-
Operating Temperature: 18–30°C (64–86°F)
-
Storage Temperature: 0–50°C (32–122°F)
-
Relative Humidity: 20–80%, non-condensing
Safety & Compliance
-
Meets CE and FDA regulatory standards
-
Electromagnetic compatibility for cath lab environments
-
Designed for sterile field use with disposable catheters
Software Features
-
Real-time imaging and physiology overlays
-
Automated measurement tools for vessel sizing, lesion length, and plaque burden
-
Multi-modal data visualization (IVUS + physiology)
-
Report generation and integration with hospital information systems

Reviews